Styles applications typically a single door hatch is utilized for ingress.
Ibc roof hatch.
Understanding styles of roof hatches their applications and codes helps architects and building owners specify the right product in the right place while being code compliant.
2015 ibc 1011 12 2 roof access states.
Roof hatches and scuttles provide safe and convenient access up to the roof areas on commercial buildings.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Bilco roof hatches provide safe and convenient access to roof areas by means of an interior ladder ship stair or service stair.
Fasteners for asphalt shingles shall be galvanized stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 2 67 mm shank with a minimum 3 8 inch diameter 9 5 mm head of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 1 mm into the roof sheathing.
In buildings of 4 or more stories above grade plane ibc requires certain buildings to provide access to the roof.
A variety of special sizes are also available to provide an accessible way to install or remove large pieces of equipment from a building.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5 m 2 in area and having a minimum dimension of 2 feet 610 mm.
Guard shall be provided where the roof hatch opening is located within 10 feet 3 05m of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 76 2cm above the floor roof or grade below.